SHOOTERS'
FORUM

Forum Registration
Precision Reloading Cabelas.com Midsouth Shooters SWFA.com Grafs.com

NOTICE to FORUM MEMBERS: CLICK HERE to go to the UPDATED FORUM. Log in with SAME User Name and SAME Password. All the threads and posts are now there. You should find the NEW FORUM faster and easier to navigate.

Please CHANGE YOUR BOOKMARKS for our forum to: http://accurateshooter.com/forum/

THIS FORUM is now archived. POSTING and THREAD CREATION is halted. You can still READ and SEARCH existing posts.

A Message Board, Guestbook, or Poll hosted for your website.
New Posts
Forums > Reloading Forum (All Calibers) > seating questions / help.
 

Thread Tools  | Search This Thread 
Reply
 
Author Comment
 
JLM
    10/20/09
Reply with quote#1

I thought I posted this last night, but I don't see anything for it today. Must have done something wrong.

I have a 6BR no turn neck. My Forster die has been reamed for no turn necks. I use the expander ball.

I've been using a Wilson micrometer seater. I've been measuring OAL to tip on 105 Amax's and 107 smk's and have been getting measurements all over the place +/- .030". Yesterday I received my sinclair bullet comparator (looks like a nut with different caliber holes drilled in it. Anyway with that the spread on the OAL is MUCH tighter but still some are in or out .001" from what I was wanting.

I am using the die by hand. In unsized new Lapua brass I'd say the wilson seater is almost impossible to use by hand. A FL size makes all the difference. All case necks are chamfered 45 deg.

My questions are: Is this the limit of the precision from this seater AND the measuring devices? Would some seating lube correct the problem? If so what lube. Is an arbor press the answer to my problems?


Thanks for the help,
JLM
gunamonth
    10/20/09
Reply with quote#2

Quote:
Is an arbor press the answer to my problems?


Don't know what other problems you may have but an arbor press, even an el-cheapo, will cure your hurting palms and ensure each bullet is fully seated.

Quote:
Is this the limit of the precision from this seater AND the measuring devices?


Depends on the bullet. With those that have a very consistant shape such as Berger, BIB, JLK, and most all of the customs the Wilson seater will do +/- 0.0005". The Sierra and Hornady, not so much. The Sinclair or Hornady tool with a repeatable caliper should be within the resolution of the tool - again 0.0005".
JLM
    10/20/09
Reply with quote#3

Thanks Gunamonth,

I was figuring I needed an arbor press. Yes the palms can get a little fatigued.

Measuring to the bullet tip just wasn't working. The comparator made everything look better. I'll have to try some bergers.

Take care,
JLM
Previous Thread | Next Thread
Reply

 
Bookmarks
 
Digg Diggdel.icio.us del.icio.usStumbleUpon StumbleUponGoogle Google
 
Please Visit Our Sponsors

You Can Help Support 6mmBR.com by Making a Small, Secure Donation.

Daily Shooter's BulletinForum FAQ





Sponsored Searches Help Support this Forum

RULES for Classifieds

All sellers must have a complete Forum profile, including City, State, and VALID email address.

All sellers must enable their email and private message options.

All sellers must mark sold items as "SOLD".

All sellers must disclose if the item is posted for sale elsewhere and state that the item is "subject to prior sale."

Any seller who uses deceptive photos, lies about key components or major defects will have his advert deleted without notice and is subject to being banned from the Forum forever.

All sellers must provide current true identity, phone number and address to buyer on request.


POLICY VIOLATIONS

Any member selling/trading any item(s) on this board who accepts monies from another member without sending out the items purchased will be permanently banned from the Forum.